Static Load Test and Finite Element Analysis on Full-scale Model of Utility Tunnel Structure without Axillary Angle

YI Weijian,YAN Liang,PENG Zhen

Abstract

Monolithic precast concrete utility tunnel structure generally does not set the axillary angle. In order to study the failure mechanism, bearing capacity and crack condition of the structure of the utility tunnel without axillary angle, a static concentric load test was performed on the full-scale model of a multicellular utility tunnel with and without axillary angle. The results showed that the crack width of the long span roof of the utility tunnel reached a short time limit of 0.133 mm for the control condition,and the roof finally showed shearing damage. The finite element model was established and the test results were used to verify the model. Then, the nonlinear finite element method was used to analyze the utility tunnel model,and the results show that the mechanical properties of the section model under both uniform load and concentric load are basically the same. According to the segmental model test and nonlinear finite element analysis, the design control conditions for the utility tunnel structure with and without axillary angle are the maximum crack width, but the ultimate damage is the shearing failure of the roof. The structure performance of the utility tunnel without axillary angle is close to that of the utility tunnel with axillary angle by properly increasing the longitudinal bar ratio of the roof.

 

 

Keywords: utility tunnel without axillary angle,  full-scale test,  finite element analysis,  static load,  crack control


Full Text:

PDF


References


]LEI S X.Utility tunnel and pipeline shield [M]. Beijing:China Railway Publishing House,2015:1—2.(In Chinese)

] CHENG H Y. Discussion and practice of utility tunnel [J]. Shanghai Municipal Engineering,1995(1):36—46.(In Chinese)

]HU M H,LIN H. A summary on the construction of utility tunnels in China and other countries [J]. Optimization of Capital Construction,2004,25(3):7—10.(In Chinese)

] HE C,KOIZUMI A. Study on seismic behavior and seismic design methods in transverse direction of shield tunnels [J]. Structural Engineering & Mechanics,2001,11(6):23—46.

] SHI X J,CHEN J,LI J. Shaking table test on under-ground utility tunnel [J]. Journal of Earthquake Engineering and Engineering Vibration,2008,28(6):116—123.(In Chinese)

]SHI X J. Experimental study on large shaking table of under- ground integrated pipe gallery under non -uniform seismic excitation [D]. Shanghai:College of Civil Engineering,Tongji University,2008:167—169.(In Chinese)

]CHEN J,SHI X J,LI J. Shaking table test on utility tunnel under non -uniform seismic excitations :experimental results[J]. Journal of Earthquake Engineering & Engineering Vibration, 2010,30(2):123—130.(In Chinese)

]HU X,XUE W C. Experimental study of mechanical properties of PPMT [J]. China Civil Engineering Journal,2010,43(5):29—37. (In Chinese)

] TIAN Z X. Experimental research on force performance of pre-cast concrete underground comprehensive municipal tunnel [D]. Harbin:College of Civil Engineering, Harbin Institute of Technology,2016:120—124.(In Chinese)

]PENG Z. Full -scale test and finite element analysis of the municipal tunnel [D]. Changsha:College of Civil Engineering, Hunan University,2017:65—67.(In Chinese)

] JGJ 1—2014 Technical specification for precast concrete structures [S]. Beijing:China Architecture & Building Press,2014:19—25. (In Chinese)