Experimental Study on Seismic Behavior of Square Concrete-filled Steel Tube Column with End Ribs

WANG Mengfu, YANG Mian

Abstract

In order to improve the bearing capacity and ductility of square concrete-filled steel tube (CFST) column,this paper proposed a new structure scheme,adding ribs at the end of CFST column. Three CFST columns with end ribs were designed and produced. Pseudo static test was conducted,and seismic behaviors including the bearing capacity,hysteresis curves,skeleton curves and displacement ductility were obtained. Compared with the conventional CFT columns,experimental results indicated that the hysteretic loop curve of the test specimens dissipated large energy,and the decline of the skeleton curve was not significant. The ultimate displacement increased obviously by 44.4%,65.3% and 29.3%,respectively. The ductility increased by 27.0%,51.3% and 6.7%,respectively. The CFST columns with ribs exhibited good energy dissipation capacity and their seismic performance was significantly improved with larger ductility.

 

 

Keywords: square concrete-filled steel tube column,  end ribs,  pseudo static test,  seismic behavior


Full Text:

PDF


References


LIU Jin, DING Faxing, GONG Yongzhi, et al. Round steel tube concrete short column pressure performance study [J]. Journal of Hunan University: Natural Sciences, 2015, 42 (11): 33—40.(In Chinese)

LI Jia, YI Weijian. Concrete-filled steel tube bending component hysteretic model analysis [J]. Journal of Hunan University:Natural Sciences. 2002, 29(3): 132—136.(In Chinese )

LI Deshan, ТАО Zhong, WANG Zhibin. Concrete-filled steel tube column-steel beam signal spiral link node static performance test research [J ]. Journal of Hunan University: Natural Sciences, 2015, 42(3): 43—49.(In Chinese)

HUANG Hong. ZHANG Ange, LI Yi, et al. Experimental study and finite element analysis on the ribbed square concrete-filled steel stub columns under axial load [J]. Journal of Building Structure, 2011, 32(2): 75—82.(In Chinese)

TAO Zhong, HAN Linhai, WANG Zhibin. Experimental behavior of stiffed concrete-filled thin-walled hollow columns structural stub columns [J]. Journal of Constructional Steel Research. 2005, 61 (7)s 962-983.

ZHANG Yaochun, XU Chao, LU Xiaozhe. Hysteretic behavior of square concrete-filled thin-wall steel stub columns with ribs [J]. Journal of Southeast University, 2007, 37(1 ): 100—106.(In Chinese)

МАО X Y, XIAO Y. Seismic behavior of confined square CFT columns[J], Engineering Structures, 2006, 28 (10): 1378 -1386.

DU Xikai. Experimental research and theoretical analysis of seismic behavior of concrete-filled steel tube beam-columns under cyclic loading [D]. Tianjin: School of Civil Engineering, Tianjin University, 2010: 17—33.(In Chinese)

GB/T 228. 1 2010 Metallic materials tensile testing part 1: method of test at room temperature [S]. Beijing: Standard Press of China, 2002: 9—18. (In Chinese)

GB/T 50081 2002 Standard for test method of mechanical properties on ordinary concrete [S]. Beijing: China Architecture & Building Press, 2002: 4 — 12. (In Chinese)

HAN Linhai. Concrete-filled steel stub structure: theory and practice[M . 2nd ed. Beijing: Science Press. 2007: 227 — 229. (In Chinese)

JBJ 101 96 Specification of testing methods for earthquake resistanct building [S]. Beijing: China Architecture & Building Press. 1997; 9—13.(In Chinese)


Refbacks

  • There are currently no refbacks.