Structural Performance Analysis of a Three-pylons Suspension Bridge Considering Fire Accident in the Vicinity of Middle Steel Pylon

MA Rujin, GUI Chuanjie, MA Minglei

Abstract

The yield strength of the steel component gradually decreases under high temperature. As a result, the structural performance of the steel component on the bridges will be greatly affected by the on-deck fire disaster. Taking the steel pylon of a three-pylon suspension bridge as an example, this paper mainly studied the influence of the fire disaster on the structural performance of the steel pylon and the entire bridge. First of all, the temperature distribution inside the fire and steel pylon was obtained by the numerical simulation of different on-deck fire scenarios near the middle steel pylon. Secondly, the change of the structural static performance of the bridge under different fire scenarios was obtained by a nonlinear analysis. The results showed that under the effect of a serious vehicle fire, larger than 80 m2 area of the middle steel pylon was under the temperature up to 800 ℃, and the maximum temperature would exceed 1 000 ℃, which can greatly affect the structural performance of the steel pylon. Obvious changes of stress and formation of the middle steel pylon were discorverd, which means 4.6 mm vertical residual deformation, 53.8 mm lateral residual deformation and 70 MPa stress reduction. However, the stress and deformation of the main cable and girder only showed minor changes.

 

 

Keywords: structural analysis,  three-pylons suspension bridge,  middle steel pylon,  fire accident,  management and maintenance


Full Text:

PDF


References


MARIA G. IGNACIO P Z. VENKATESH K. et al. Fire hazard in bridges, review, assessment and repair strategies [J]. Engineering Structures. 2012 (35);89 — 98.

BLINOV V I. KHUDYAKOV G. On certain regularities of diffusion burning of liquids [J]. Doklady Akademii Nauk SSSK. 1957(113), 241 — 244.

MENDES P A. VALENTE J C. BRANCO F A. Simulation of ship fire under Vasco da Gama Bridge[J], ACI Struct J. 2000, 97 (2): 285-290.

DOTREPPE J C, MAJKUTS. FRANSSEN J M. Failure of a tied-arch bridge submitted to a severe localized fire[C]//IAB-SE Symposium. Lisbon: Structures and Extreme Events. 2006:15-22.

KODUR V R, GU L. GARLOCK M E. Review and assessment of fire hazard in bridges[C]//Journal of the Transportation Research Board No. 2172. Washington DC: Transportation Research Board of the National Academies. 2010: 23 — 29.

IGNACIO P Z. GARLOCK M E M. A 3D numerical analysis of a typical steel highway overpass bridge under a hydrocarbon fire[C]//Proceedings of the Fifth International Conference for Structures in Fire. East Lansing(USA) .2010.11 — 18.

CHENG Yuan ping. CHEN Liang. ZHANG Mengjun. The models and experimental testing method of heat release rate of fuel during the development of fire [J]. Fire Safety Science. 2002. 11(2):70—74. (In Chinese)

I.I G Q. WANG P J. Advanced analysis and design for fire safety of steel structures [М]. Hangzhou:Zhejiang University Press. 2012:15-17.

HAACK A. Fire protection in traffic tunnels: general aspects and results of the eureka project [C] //Tunnellingand Underground Space Technology. Amsterdam: Elsevier Science Ltd. 1998: 377-381.

CAFARO E. BERTOLA V. Fires in tunnels: experiments and modelling [J]. The Open Thermodynamics Journal. 2010 (4) :156 166.

NI Zhaopeng. CHEN Haiyun. Present situation and development trend for tunnel fireproof technigue at home and abroad [J]. Transpo World.2003.3(2) s28 — 31. (In Chinese)

LACROIX D. New French recommendations for fire ventilation in road tunnels[C]//Conf, on Aerodynamics and Venti-laion of Road Tunnels. Aosta ( Italy): Mechanical Engineering Publications. 1997:103 — 124.


Refbacks